Sign In | Join Free | My burrillandco.com
Home > IPL Laser Machine >

No Pain Spa Opt IPL Shr Permanent Hair Removal Machine For Skin Tightening

    Buy cheap No Pain Spa Opt IPL Shr Permanent Hair Removal Machine For Skin Tightening from wholesalers
     
    Buy cheap No Pain Spa Opt IPL Shr Permanent Hair Removal Machine For Skin Tightening from wholesalers
    • Buy cheap No Pain Spa Opt IPL Shr Permanent Hair Removal Machine For Skin Tightening from wholesalers

    No Pain Spa Opt IPL Shr Permanent Hair Removal Machine For Skin Tightening

    Ask Lasest Price
    Brand Name : XYY
    Model Number : xy02
    Certification : ce,iso,tuv,fda
    Price : usd 3000-5000per set
    Payment Terms : T/T , Western Union
    Supply Ability : 3000sets per month
    Delivery Time : 3-7 working days
    • Product Details
    • Company Profile

    No Pain Spa Opt IPL Shr Permanent Hair Removal Machine For Skin Tightening

    No pain spa used white effective wholesale opt IPL shr permanent hair removal



    Applications of SHR


    1. Hair removal ( normal mode and SHR mode) : All kinds of skin types, and hair colors.


    2. Skin tightening: Skin lifting, improve flexibility and skin tone condition, anti- aging.


    3. Skin rejuvenation: Wrinkles reduction, freckles,skin whitening, shrink large pores.


    4. Vascular: Red face, red nose, spider veins,vascular removal.



    Technical parameter of machine


    Wavelength590nm/640nm-1200nm
    Handpiece number2 piece with 5 filters
    Spot size12*30(mm) &15*50(mm)
    Cooling systemsemiconductor+air+water+cooling gel
    IPL light energy1-50(j/cm²)
    Pulse duration1-10ms
    Pulse NO.1-6
    SHR pulse duration1-7ms
    SHR frequency1-10HZ
    SHR energy1-50J/CM2
    Skin cooling-4°c-10°c
    Display10.4″color touch screen
    Output power2500W
    Voltage110v,50hz or 220v,60hz
    Machine Size(L*W*H):42cm*38cm*90cm
    Net weight60kg
    Gross weight91kg
    Package size69cm*64cm*102cm

    Working principle of SHR hair removal:


    SHR- Super Hair Removal, it's a revolutionary technology of hair removal which is having

    a sweeping success. (adopt technology AFT, EDF).


    SHR combines laser technology and the benefits of the pulsating light method achieving practically painless results.


    SHR (Super Hair Removal ) is the advanced IPL mode. Its shots frequency can reach 10Hz per second, while traditional IPL's shots frequency is just 1Hz. You can just slide the SHR handle on skin quickly. We call this treatment method "IN-MONTION", means slide quickly on skin. It represents a breakthrough in permanent hair removal with light technology. The treatment is more pleasant than with the conventional systems and your skin is better protected.



    Hair removal of OPT elight machine


    1. Cut or shave hair to 1-2mm or ask patients to shave at home 2-3 days before treatment.
    2. Clear treatment area.
    3. Turn on machine,
    1). Use SHR, adjust pulse width at 7ms, frequency 5HZ, energy 10J/cm2.
    2). Use normal hair removal treatment, put the 640nm or 690nm filter into the slot, select
    "hair removal",adjust the parameter, set it to ‘ready’ .
    4. Put cooling gel on treatment area about 2mm.
    5. Wear protect goggles for patient and operator.
    6. Shot the treatment area, let the crystal tip to touch cooling gel, You are permitted to have 1/3 overlapping on treatment area.
    7. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients feel warm or hot, you may put ice bag on treatment area until heat disappear.


    Skin rejuvenation

    1. Clear treatment area.
    2. Turn on machine ,put the 560nm filter into the slot, select "skin rejuvenation",adjust the
    parameter, set it to ‘ready’ .
    3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4°C.
    4. Wear goggles for patient and operator
    5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have1/3 overlapping on treatment area.
    6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling disappears.


    Pigmentation Therapy

    1. Clear treatment area.
    2. Turn on machine ,put the 480nm or 530nm filter into the slot, select "pigmentation
    therapy",adjust the parameter, set it to ‘ready’ .
    3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
    refrigerator to keep temperature of gel during 0-4°C.
    4. Wear goggles for patient and operator
    5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
    1/3 overlapping on treatment area.
    6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
    feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
    disappears.


    Vascular Therapy

    1. Clear treatment area.
    2. Turn on machine ,put the 580nm filter into the slot, select "vascular therapy",adjust the
    parameter, set it to ‘ready’ .
    3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
    refrigerator to keep temperature of gel during 0-4°C.
    4. Wear goggles for patient and operator
    5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
    1/3 overlapping on treatment area.
    6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
    feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
    disappears.


    Acne Therapy

    1. Clear treatment area.
    2. Turn on machine ,put the 430nm filter into the slot, select "acne therapy",adjust the
    parameter, set it to ‘ready’ .
    3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
    refrigerator to keep temperature of gel during 0-4°C.
    4. Wear goggles for patient and operator
    5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
    1/3 overlapping on treatment area.
    6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
    feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
    disappears.

    Wrinkle removal

    1. Clear treatment area.
    2. Turn on machine ,put the 580nm filter into the slot, select "wrinkle removal",adjust the
    parameter, set it to ‘ready’ .
    3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
    refrigerator to keep temperature of gel during 0-4°C.
    4. Wear goggles for patient and operator
    5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
    1/3 overlapping on treatment area.
    6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
    feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
    disappears.



    Quality No Pain Spa Opt IPL Shr Permanent Hair Removal Machine For Skin Tightening for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Xinyingyue Beauty Equipment Science And Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)